Show simple item record

dc.contributor.authorBautista-Salinas, Daniel
dc.contributor.authorHammer, Peter E.
dc.contributor.authorPayne, Christopher J.
dc.contributor.authorWamala, Isaac
dc.contributor.authorSaeed, Mossab
dc.contributor.authorThalhofer, Thomas
dc.contributor.authordel Nido, Pedro J.
dc.contributor.authorWalsh, Conor J.
dc.contributor.authorVasilyev, Nikolay V.
dc.date.accessioned2022-02-04T22:15:11Z
dc.date.available2022-02-04T22:15:11Z
dc.date.copyright5/20/2020 12:00:00 AM
dc.date.issued2020
dc.identifier.issn1932-6181
dc.identifier.othermed_014_03_031003.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4275192
dc.description.abstractSoft robotic devices have been proposed as an alternative solution for ventricular assistance. Unlike conventional ventricular assist devices (VADs) that pump blood through an artificial lumen, soft robotic VADs (SRVADs) use pneumatic artificial muscles (PAM) to assist native contraction and relaxation of the ventricle. Synchronization of SRVADs is critical to ensure maximized and physiologic cardiac output. We developed a proof-of-concept synchronization algorithm that uses an epicardial electrogram as an input signal and evaluated the approach on adult Yorkshire pigs (n = 2). An SRVAD previously developed by our group was implanted on the right ventricle (RV). We demonstrated an improvement in the synchronization of the SRVAD using an epicardial electrogram signal versus a RV pressure signal of 4 ± 0.5% in heart failure and 3.2 ± 0.5% during actuation for animal 1 and 7.4 ± 0.6% in heart failure and 8.2% ± 0.8% during actuation for animal 2. Results suggest that improved synchronization is translated in greater cardiac output. The pulmonary artery (PA) flow was restored to a 107% and 106% of the healthy baseline during RV electrogram actuation and RV pressure actuation, respectively, in animal 1, and to a 100% and 87% in animal 2. Therefore, the presented system using the RV electrogram signal as a control input has shown to be superior in comparison with the use of the RV pressure signal.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleSynchronization of a Soft Robotic Ventricular Assist Device to the Native Cardiac Rhythm Using an Epicardial Electrogram
dc.typeJournal Paper
dc.journal.volume14
dc.journal.issue3
dc.journal.titleJournal of Medical Devices
dc.identifier.doi10.1115/1.4047114
dc.journal.fristpage031003-1
dc.journal.lastpage031003-8
dc.page8
dc.treeJournal of Medical Devices:;2020:;volume( 014 ):;issue: 003
dc.contenttypeFulltext