Pulsed Eddy Current Response to General Corrosion in Concrete Rebar
View/ Open
Date
2020Author
Eddy, Ian
Underhill, P. R.
Morelli, J.
Krause, T. W.
Metadata
Show full item recordAbstract
Corrosion of carbon steel rebar in concrete structures, such as highway bridges and buildings, has a direct impact on their structural integrity since the rebar provides the tensile strength within the structure. Rebar strength depends on the remaining effective radius of a given rod. Long-time decay up to 0.1 s, in the transient response of pulsed eddy current (PEC), was examined as a potential method to quantify general corrosion in ferromagnetic rebar. The transient response of a coaxial solenoidal drive–receive coil pair, oriented parallel to the rebar axis, was analyzed over a range of distances into the concrete (liftoff) and rebar radii. At long times, the single exponential decay constant was largely independent of liftoff. A power law relationship for the characteristic decay time, consistent with long-time diffusion of electromagnetic fields into a rod, was observed. The intercept of a best-fit line to measured voltage decay decreased exponentially with liftoff and maintained a measurable response up to 110 mm distance for a 25 mm (1 in.) diameter rebar. This exponential decay was present in 22 mm (7/8 in.), 19 mm (3/4 in.), and 15 mm (5/8 in.) samples as well. Reported results demonstrate the potential for PEC to quantify remaining cross-sectional area of rebar in concrete structures.