    Performance Analyses of Photovoltaic Thermal Integrated Concentrator Collector Combined With Single Effect Absorption Cooling Cycle: Constant Flow Rate Mode

    Thumbnail
    View/Open
    jert_142_12_121305.pdf (871.5Kb)
    Date
    2020
    Author
    Meraj, Md.
    Khan, M.E.
    Azhar, Md.
    Metadata
    Show full item record
    Abstract
    In the present communication, performance analyses of interconnected N number of fully covered semitransparent photovoltaic thermal integrated concentrator collectors combined with single effect vapor absorption refrigeration system have been carried out. The proposed system was analyzed under the constant mass flowrate of collectors’ fluid. Mathematical expressions have also been derived for generator temperature of the absorption unit as a function of both design and operating parameters. Further, simulations have been performed for a typical day of May month of New Delhi climatic conditions. Performance parameters have been evaluated such as collector exit temperature, generator inlet temperature, electrical power output, electrical efficiency, overall thermal energy gain, instantaneous thermal efficiency, overall exergy gain and coefficient of performance of the absorption system. The simulation code has been written in matlab. From the present analyses, the following salient conclusions have been drawn: Operating generator temperature of the absorption system is suitable for five number of photovoltaic thermal-integrated parabolic concentrator collector connected in series. The proposed system will continue operating for 5 h during May month in New Delhi climate conditions. The maximum solar coefficient of performance, refrigeration coefficient of performance, and exergy coefficient of performance are reported as 0.1551, 0.8344, and 0.2697, respectively, for the proposed novel system under given design and operating conditions. Additionally, the effects of other design parameters of this novel system have also been investigated.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4274984
    Collections
    • Journal of Energy Resources Technology

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV