Show simple item record

dc.contributor.authorNagaraja, Srinidhi
dc.contributor.authorLoughran, Galyna
dc.contributor.authorGandhi, Anup
dc.contributor.authorInzana, Jason
dc.contributor.authorBaumann, Andrew P.
dc.contributor.authorKartikeya, Kumar
dc.contributor.authorHorner, Marc
dc.date.accessioned2022-02-04T14:35:05Z
dc.date.available2022-02-04T14:35:05Z
dc.date.copyright2020/03/13/
dc.date.issued2020
dc.identifier.issn2377-2158
dc.identifier.othervvuq_005_01_011002.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4273962
dc.description.abstractVerification, validation, and uncertainty quantification (VVUQ) can increase confidence in computational models by providing evidence that a model accurately represents the intended reality of interest. However, there are currently few examples demonstrating the application of VVUQ best practices for medical devices. Therefore, the objectives of this study were to understand the reproducibility and repeatability of experimental testing and finite element analysis (FEA), perform VVUQ activities that guide the development and refinement of a finite element model, and document best practices for future research. This study focused on experiments and simulations of three-point bend testing, which is a fundamental element of a hierarchical validation study of medical devices (e.g., spinal rod-screw systems). Experimental three-point bend testing was performed at two laboratories using medical-grade titanium (Ti-6Al-4V) spinal rods. FEA replicating the experimental test was performed by four independent institutions. Validation activities included comparing differences in mechanical properties between FEA and experimental results, where less than 10% difference was observed for all quantities of interest. Computational model uncertainties due to modeling assumptions and model input parameters were estimated using the sensitivity coefficient method. An importance factor analysis showed that rod diameter was the parameter driving uncertainty in the initial elastic region, while the material model is the primary contributor beyond this point. These results provide a proof of concept in the use of VVUQ for the use of FEA for medical device applications.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleVerification, Validation, and Uncertainty Quantification of Spinal Rod Computational Models Under Three-Point Bending
dc.typeJournal Paper
dc.journal.volume5
dc.journal.issue1
dc.journal.titleJournal of Verification, Validation and Uncertainty Quantification
dc.identifier.doi10.1115/1.4046329
dc.page11002
dc.treeJournal of Verification, Validation and Uncertainty Quantification:;2020:;volume( 005 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record