    A Study of Improving the Formability of the Commercial Pure Titanium Foils

    Thumbnail
    View/Open
    mats_142_3_031005.pdf (2.397Mb)
    Date
    2020
    Author
    Zhu, Jiaqi
    Nunnally, Alex
    Gau, Jenn-Terng
    Xu, Siguang
    Metadata
    Show full item record
    Abstract
    In order to obtain the optimum forming process for commercial pure titanium grade 2 foils, a series of tensile tests and micro scale limited dome height (µ-LDH) tests at four temperatures, and meso scale limited dome height tests (meso-LDH) with three punch speeds were conducted on the as-received foils with a thickness of 75 µm. The effects of temperature, geometry, and high-velocity impact were investigated to understand their influences on the formability of the foils. It has been found in the tensile tests that the formability can be improved by elevating temperatures; this has been validated by the µ-LDH tests. Based on forming limit diagrams (FLDs) of the meso-LDH specimens, the high-velocity impact forming process results in not only much better formability but also more uniform thickness distributions than the quasi-static. By analyzing the fractographical scanning electron microscope (SEM) pictures of the meso-LDH specimens, it has been proven that the formability of the foils by using high-velocity impact process is superior to the conventional process. Furthermore, high-velocity impact causes forming limit curve (FLC) to shift in the upper right direction on the right-hand side of FLD. Therefore, it is suggested forming the foils by using high-velocity impact forming process at the elevated temperature for obtaining a better formability and more uniform thickness distribution. It is also recommended to make the radius of the LDH hemisphere punch close to the smallest feature of the designed products for obtaining more accurate FLCs.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4273820
    Collections
    • Journal of Engineering Materials and Technology

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV