• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Quantification of Passive Ventilation Produced by Manual Chest Compressions Using a New Cardiopulmonary Resuscitation Feedback Device

    Thumbnail
    View/Open
    med_014_02_024503.pdf (749.0Kb)
    Date
    2020
    Author
    Taleb, Lhoucine Ben
    Essoukaki, Elmaati
    Mouhsen, Azeddine
    Lyazidi, Aissam
    Assir, Abdelhadi
    Harmouchi, Mohammed
    Rattal, Mourad
    Metadata
    Show full item record
    Abstract
    Several studies have shown that chest compressions (CC) alone may produce in addition to blood circulation, a short-term passive ventilation. However, it is not clear whether high CC quality may produce in even greater amount of ventilation volumes. The aim of this study was to evaluate whether CC, using a new feedback device, can produce a substantial and sustainable passive volumes compared to standard CC. Thirty inexperienced volunteers performed CC for 2 min on a developed thoracic lung model and using a new feedback device. Participants were randomized into two groups that performed either CC with feedback first, followed by a trial without feedback, or vice versa. Efficient compression rate (correct CC rate and depth simultaneously) was significantly higher in feedback session (43.6% versus 25.5%; P = 0.006). As well, CC rate and depth efficiency were improved with feedback. Moreover, average tidal volumes and minute volumes that occurred during CC alone were significantly improved in feedback session (79.8 ± 5 ml versus 72.9 ± 7 ml) and (8.8 l/min versus 7.9 l/min), respectively (P < 0.001). Yet, no significant difference was found between the first and the 90th second interval (9.04 l/min versus 8.68 l/min, P = 0.163) in the feedback session. Conversely, a significant difference was evident after the first 15th seconds interval without feedback (8.77 l/min initially versus 8.38 l/min; P = 0.041). This study revealed that the new CPR feedback device improved CC quality in inexperienced volunteers. As well, the passive ventilation volumes were significantly increased and sustained when the device was used.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4273723
    Collections
    • Journal of Medical Devices

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV