dc.description.abstractA study was conducted to explore the applicability of recurrence and recurrence quantification analysis (RQA) to the detection of process failures in spouted bed reactor systems. Three different potential failure modes were examined in a transparent, cold flow slot-rectangular spouted bed. These being, a simulated air leak from a side wall of the reactor, a simulated gas leak from the top wall of the reactor, and simulated agglomeration of solids via introduction of larger “klinker” particles. Bed pressure drop time history data were collected and analyzed via generation of recurrence plots (RPs) and RQA parameters. In general, the simulated agglomeration case was quite easily detected via ever RQA Parameter examined, whereas the simulated air leaks were detected by only a single RQA parameter.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleProcess Failure Detection via Recurrence Quantification Analysis in a Slot-Rectangular Spouted Bed
dc.typeJournal Paper
dc.journal.volume142
dc.journal.issue7
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.4046457
dc.page70906
dc.treeJournal of Energy Resources Technology:;2020:;volume( 142 ):;issue: 007