    Stress–Strain Behavior of FRP-Confined Recycled Aggregate Concrete in Square Columns of Different Sizes

    Thumbnail
    View/Open
    %28ASCE%29CC.1943-5614.0001150.pdf (2.888Mb)
    Date
    10/1/2021
    Author
    Guangming Chen
    Junjie Zhang
    Yufei Wu
    Guan Lin
    Tao Jiang
    Metadata
    Show full item record
    Abstract
    The application of recycled aggregate concrete (RAC) has so far mainly been limited to nonstructural components because of its inferior short- and long-term performance compared with normal concrete. Encasement of RAC with a fiber-reinforced polymer (FRP) tube has been demonstrated to be an effective technique to improve both the mechanical properties and durability of RAC. A number of studies have been carried out on FRP-confined RAC in circular columns. However, only a limited number of studies have examined the behavior of FRP-confined RAC in rectangular columns, and the existing test specimens were all small-scale. Existing studies have shown that there may exist a significant behavioral difference between small- and large-scale FRP-confined rectangular concrete columns (i.e., column size effect). Against this background, a first-ever experimental study on glass FRP (GFRP)-confined square RAC columns of three different sectional widths ranging from 200 to 400 mm was conducted and the results are presented in this paper. The same FRP confinement stiffness was adopted for the columns of different sizes so that the possible column size effect could be examined. The test results showed that the size effect indeed existed in the test FRP-confined square RAC columns and the presence of recycled aggregate amplified such effect. The size effect should be considered in the design of such columns especially when the coarse aggregate replacement ratio is relatively large. The accuracies of three existing strength models for FRP-confined normal concrete in square columns were also evaluated using the test results.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4272848
    Collections
    • Journal of Composites for Construction

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV