• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Self-Centering Bridge Bent with Stretch Length Anchors as a Tension-Only Hysteretic Hybrid System

    Thumbnail
    View/Open
    %28ASCE%29ST.1943-541X.0003146.pdf (4.548Mb)
    Date
    10/1/2021
    Author
    Dipendra Thapa
    Chris P. Pantelides
    Metadata
    Show full item record
    Abstract
    Accelerated bridge construction (ABC) incorporates innovative techniques to reduce construction time and traffic disruption. The objective of the research was to design, build, and test a seismically resilient bridge bent using ABC methods, which can self-center, thus remaining functional after a large earthquake with minimal repairs. The design criteria were to achieve a drift ratio of 2.0% without concrete damage, mild steel reinforcement yielding, or post-tensioned (PT) bars yielding. A tension-only hybrid system was designed and tested with similar characteristics to conventional hybrid systems. The distinguishing feature of the system is that the hysteretic component consists of stretch length anchors (SLA) designed to elongate and dissipate hysteretic energy only in tension. SLAs are intentionally built, so they do not experience compression forces, do not need to be protected against buckling, and have a long fatigue life; moreover, they do not impede recentering because hysteretic energy dissipation occurs only under tensile stress. SLAs are readily available; they are affordable and are easy to replace after an earthquake. A two-column precast concrete bridge bent was tested under quasi-static cyclic loads. Unbonded post-tensioned (PT) bars were used to connect the reinforced concrete cap-beam, columns, and footings for recentering the structural system. Column mild steel reinforcement did not cross the column-to-footing or column-to-cap-beam interfaces. SLAs were attached at the top and bottom of the column externally and were constructed so they could be replaced easily after an earthquake. SLAs yielded and elongated in tension at a 1.2% drift ratio; the PT bars and gravity load were effective in self-centering the structural system. The specimen met the design criteria, with a maximum residual drift ratio of 1.1% at a maximum imposed 6.0% drift ratio, while the structural system experienced repairable damage.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4272788
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV