• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Bridge Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Bridge Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Seismic Performance of Precast Segmental Concrete-Filled Steel-Tube Bridge Columns with Internal and External Energy Dissipaters

    Thumbnail
    View/Open
    %28ASCE%29BE.1943-5592.0001792.pdf (2.685Mb)
    Date
    11/1/2021
    Author
    Dan Zhang
    Ning Li
    Zhong-Xian Li
    Metadata
    Show full item record
    Abstract
    The prefabricated segmental column using posttensioning technology has become an ideal candidate for rapid and environmentally friendly construction. To avoid damage to the segment joint during a seismic event and enhance its energy dissipation (ED), a precast segmental concrete-filled steel-tube (PSCFST) bridge column with internal or external ED bars is proposed. The seismic performance and resilience of the PSCFST bridge columns with internal or external ED bars are investigated. Moreover, the fiber-section model and numerical analysis are used to analyze the optimal setup angle of the external ED bar. More importantly, the deformation mechanism of the PSCFST specimen with internal or external ED bars is provided. Then, two PSCFST columns and one reference monolithic reinforced-concrete (MRC) column were designed and tested under pseudostatic loading. Owing to the confinement effect of the steel tube on the concrete of each segment, the PSCFST column has desirable performance without obvious damage, whereas the plastic hinge region of the MRC column is severely damaged. After the test with a maximum drift of 5%, the residual drift of PSCFST columns is very small, only 0.175–0.209%, whereas the residual drift of the MRC specimen is 3.632%. To investigate the resilience performance of PSCFST column, one column was reloaded after the replacement of the external ED bars. Compared with the original specimen, the reloaded column shows excellent self-centering behavior, no obvious damage, and very small residual displacement.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4272782
    Collections
    • Journal of Bridge Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV