• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Pipeline Systems Engineering and Practice
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Pipeline Systems Engineering and Practice
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Optimization of Water Distribution System Operation with Multiple Tanks and Pumps: Application for Asmara, Eritrea’s Water Supply System

    Thumbnail
    View/Open
    %28ASCE%29PS.1949-1204.0000580.pdf (448.6Kb)
    Date
    11/1/2021
    Author
    Ngandu Balekelayi
    Kahsay N. Zeraebruk
    Medhanie Teklemariam
    Solomon Tesfamariam
    Metadata
    Show full item record
    Abstract
    Pump energy consumption is the major operational cost of water distribution systems (WDS). Defining better pump operation policies can reduce the cost and the enhance service provided. The nonlinear hydraulic behavior of WDS makes the pump scheduling problem complex, especially in large WDS in which several tanks and pumping stations coexist. The nonlinear hydraulic behavior of WDS is captured using numerical simulation. However, the required energy calculations were computed from the flow rate and head increase after the pumping stations. There are many optimization algorithms for the reduction of the operational cost. The majority of these algorithms are applied to hypothetical case studies with reduced feasible solution spaces. When the search space becomes large and many alternatives (pumps combinations) are possible, most of the proposed algorithms fail. Thus, the application of these algorithms in real case studies is very limited, and water utility managers still rely on human expertise to schedule pump operation rather than on automatic scheduling. This paper proposes the use of a genetic algorithm for large WDS with a many tanks and pumps. Offline hydraulic simulations allow the definition of water level bounds in the tanks. The combination of the pumps is determined a priori and the optimization algorithm is run in a reduced search space. These preparations allow the genetic algorithm to identify quickly the optimal policy and reduce the cost of energy consumption. The proposed framework was applied to the WDS of the city of Asmara, Eritrea, with 12 tanks and 9 pumping stations. The results showed that the tanks controlled by pumps worked perfectly and the water level was kept within the defined ranges. However, the constraints were not fulfilled for uncontrolled tanks. This application showed the limitations of methodologies proposed in the literature, and it is suggested that further techniques be found to schedule the pump working policies of large WDS while reducing the violations of constraints.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4272664
    Collections
    • Journal of Pipeline Systems Engineering and Practice

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV