Show simple item record

dc.contributor.authorM. Abdollahi
dc.contributor.authorS. N. Moghaddas Tafreshi
dc.contributor.authorB. Leshchinsky
dc.date.accessioned2022-02-01T21:52:17Z
dc.date.available2022-02-01T21:52:17Z
dc.date.issued9/1/2021
dc.identifier.other%28ASCE%29GM.1943-5622.0002120.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4272200
dc.description.abstractExpanded polystyrene (EPS) geofoam is commonly used as lightweight fill materials in wide range of geotechnical engineering applications including protection of buried utilities and pipelines. EPS blocks are usually placed next to buried pipelines to reduce the overburden and traffic-induced pressure on them. In this paper, a new configuration of EPS blocks around the buried utility is defined and its performance under traffic loading examined. The proposed configuration consists of three buried EPS blocks. Two blocks (posts) are vertically oriented, while a capping EPS block (beam) is placed atop, leaving a void to protect the buried utility. Finally, soil cover is placed and compacted above the beam. By considering sufficient void space, the protection system will carry all the imposed load, and no stress will be incurred to the protected utility. The effects of beam thickness, soil cover thickness, EPS density, free span length between the posts, and soil cover reinforcement on the system's behavior under cyclic loading were explored through large-scale laboratory model tests. System performance enhanced when high-density EPS blocks, thicker beam and soil cover were used. The results also showed that reinforcing the soil cover with a single layer of geogrid could significantly lower the blocks' deformations and control their dynamic strain rate under cyclic loading. Finally, a three-dimensional finite-element model was developed, validated against experimental results, and used to gain more comprehensive insight into the protection system's performance under loading.
dc.publisherASCE
dc.titleProtection of Buried Utilities against Repeated Loading: Application of Geogrid-EPS Geofoam System
dc.typeJournal Paper
dc.journal.volume21
dc.journal.issue9
dc.journal.titleInternational Journal of Geomechanics
dc.identifier.doi10.1061/(ASCE)GM.1943-5622.0002120
dc.journal.fristpage04021158-1
dc.journal.lastpage04021158-15
dc.page15
dc.treeInternational Journal of Geomechanics:;2021:;Volume ( 021 ):;issue: 009
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record