    Investigation and Control of Cracks in Wet Joint of Concrete Box Girders

    Thumbnail
    View/Open
    %28ASCE%29CF.1943-5509.0001656.pdf (2.863Mb)
    Date
    12/1/2021
    Author
    Haibo Zhu
    Yang Zhao
    Xue Luo
    Rongqiao Xu
    Metadata
    Show full item record
    Abstract
    To investigate the causes of cracks in wet joints of continuous concrete box girders, we performed in situ analysis of the temperature and strain field of wet-joint concrete for a sea-crossing bridge under construction in China after casting. We developed a numerical model to compare with the field tests. The numerical results agree well with those measured in the field. Thermal stress due to the heat of hydration in concrete is the main factor causing cracks, followed by concrete shrinkage. Furthermore, we investigated some measures to minimize and control the occurrence of cracks, such as optimizing the concrete mix ratio and lowering the casting temperature of wet concrete.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4271941
    Collections
    • Journal of Performance of Constructed Facilities

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV