• Login
    View Item 
    •   DSpace Home
    • ASCE
    • ASCE-ASME Journal of Risk and Uncertainty in Engineering Systems, Part A: Civil Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • ASCE-ASME Journal of Risk and Uncertainty in Engineering Systems, Part A: Civil Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Comparative Seismic Performance Assessment of Reinforced Concrete Frame Structures with and without Structural Enhancements Using the FEMA P-58 Methodology

    Thumbnail
    View/Open
    AJRUA6.0001173.pdf (1.168Mb)
    Date
    1/1/2021
    Author
    Ke Du
    Wen Bai
    Jiulin Bai
    Deng Yan
    Maosheng Gong
    Jingjiang Sun
    Metadata
    Show full item record
    Abstract
    Adding energy dissipation devices to reinforced concrete (RC) frame structures is a commonly adopted structural enhancement in seismically active regions. In this paper, a state-of-the-art seismic performance assessment is applied to a typical fixed-base RC frame structure designed based on the current Chinese code. Two additional structural enhancements, including equipping buckling restrained braces (BRB) and designing as a base-isolated structure, are investigated. Nonlinear response history analyses were performed to assess the structural performance parameters under four different seismic hazard levels (i.e., frequently occurring earthquake, design level earthquake, maximum considered earthquake, and very rare earthquake). The seismic performance is quantified in terms of repair times, repair costs, and casualties. The intensity-based assessment method is used, and a comparative analysis is performed for each performance measure. The results show that a base-isolated structure and BRB frame structure can each effectively reduce the repair cost and repair time compared with a fixed-base frame, as the repair mostly come from nonstructural components. In addition, the casualties in the base-isolated structure are the lowest of the three structures. It should be noted that the acceleration response of the BRB frame structure is the largest among the three structures, and that its acceleration-sensitive components are seriously damaged, causing the most casualties.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4271787
    Collections
    • ASCE-ASME Journal of Risk and Uncertainty in Engineering Systems, Part A: Civil Engineering

    DSpace software copyright © 2002-2015  DuraSpace