• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Hazardous, Toxic, and Radioactive Waste
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Hazardous, Toxic, and Radioactive Waste
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Effect of Calcined Limestone on the Performance of Roughing Filter for Turbidity Removal of Palm Oil Mill Effluent

    Thumbnail
    View/Open
    %28ASCE%29HZ.2153-5515.0000607.pdf (1.006Mb)
    Date
    7/1/2021
    Author
    Arezoo Fereidonian Dashti
    Hamidi Abdul Aziz
    Mohd Nordin Adlan
    Ali Huddin Ibrahim
    Metadata
    Show full item record
    Abstract
    Malaysia is considered as a major palm oil producer in the world. Therefore, it is vital to utilize an environmentally friendly and inexpensive method to treat palm oil mill effluent (POME) in Malaysia. Nowadays, the use of natural absorbent to remove pollutants from POME has gained remarkable attention. The main objective of this research was to investigate the effect of calcinated limestone on turbidity removal and analyze the removal rate of pollution of POME. A column studies was conducted using different particle size of limestone (4, 12, and 20 mm), raw and calcinated at 800°C and 600°C at filtration rates of 20, 60, and 100 mL/min. An experimental model was conducted using central composite design (CCD) in response surface methodology (RSM). According to analysis of 3D surface respondents, the first optimum condition was at 800°C with 2 h of calcination time, flow rate of 20 mL/min, and limestone size of 4 mm. The second optimum condition was calcinated limestone at 600°C using a lower flow rate and smaller size of calcined limestone (CLS). The first and the second optimum conditions achieved turbidity removal of 68% and 62%, respectively, both of which outperform raw limestone with removal rate of 55%. Equilibrium isotherms in this study were evaluated using the Langmuir and Freundlich isotherms. The results showed that adsorption isotherm data is more fit to the Langmuir isotherm, with 0.95 R2 compared with 0.85 R2 for the Freundlich isotherm at 800°C.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4271686
    Collections
    • Journal of Hazardous, Toxic, and Radioactive Waste

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV