    On-Site Monitoring of the Moisture Content of Bridge Decks Made of Nail-Laminated Timbers

    Thumbnail
    View/Open
    %28ASCE%29ST.1943-541X.0003046.pdf (2.427Mb)
    Date
    7/1/2021
    Author
    Wanrong Zhu
    Ling Li
    Meng Gong
    Ying-Hei Chui
    Jianhui Zhou
    Metadata
    Show full item record
    Abstract
    This study summarizes the moisture content (MC) monitoring results of two nail-laminated timber (NLT) bridge decks in New Brunswick, Canada. The MC monitoring systems were installed in the NLT decks of two newly built bridges, Clark Mill Pond and Shikatehawk No. 5, in New Brunswick, recording the MC through the electrical resistance (ER) method. The calibration test was conducted to correlate the ER values (Ω) and MC values (%). It was found that the MC values varied from 9.9% to 18.2% and 12.8% to 19.7% for Clark Mill Pond Bridge over 239 days and Shikatehawk No. 5 Bidge over 189 days, respectively. Based upon these MC monitoring data, the NLT deck surfaces could likely not be prone to rotting caused by biotic attack during the monitoring period.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4270421
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV