Show simple item record

dc.contributor.authorAtsushi Suzuki
dc.contributor.authorKanako Abe
dc.contributor.authorKaho Suzuki
dc.contributor.authorYoshihiro Kimura
dc.date.accessioned2022-01-31T23:46:15Z
dc.date.available2022-01-31T23:46:15Z
dc.date.issued3/1/2021
dc.identifier.other%28ASCE%29ST.1943-541X.0002955.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4270326
dc.description.abstractIn general, a steel beam is assembled with a concrete slab using shear connectors. Recently, perfobond-shear connectors have been attracting interest because of their high shear stiffness and strength. Nevertheless, the mechanical behavior and performance of perfobond-shear connectors under a reversed cyclic stress remain unclear. For this study, cyclic loading tests were conducted on the component model of a composite beam possessing different configurations of perfobond-shear connectors, different diameters of transversal reinforcement, and different concrete strengths. The stress transfer mechanisms among components are revealed based on experimentally obtained results. Furthermore, the applicability of earlier evaluation formulas is investigated in terms of the ultimate shear strength and the load–displacement relation. Finally, a novel evaluation equation is proposed for perfobond-shear connectors subjected to fully reversed cyclic stress, reflecting the mechanical interrelation between the dowel plate and the concrete inside of the rib hole.
dc.publisherASCE
dc.titleCyclic Behavior of Perfobond-Shear Connectors Subjected to Fully Reversed Cyclic Loading
dc.typeJournal Paper
dc.journal.volume147
dc.journal.issue3
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0002955
dc.journal.fristpage04020355-1
dc.journal.lastpage04020355-12
dc.page12
dc.treeJournal of Structural Engineering:;2021:;Volume ( 147 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record