Show simple item record

dc.contributor.authorHossein Heydarinouri
dc.contributor.authorMasoud Motavalli
dc.contributor.authorAlain Nussbaumer
dc.contributor.authorElyas Ghafoori
dc.date.accessioned2022-01-31T23:45:24Z
dc.date.available2022-01-31T23:45:24Z
dc.date.issued3/1/2021
dc.identifier.other%28ASCE%29ST.1943-541X.0002923.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4270300
dc.description.abstractStringer-to-floor beam web-to-web double-angle connections are among the most fatigue-prone elements in old riveted bridges. These connections are often designed to carry only shear loads. However, in these elements, fatigue damage occurs because of the out-of-plane deformation of the connections, which is ignored in the original design. In this study, a new retrofitting system is developed to reduce the out-of-plane deformation of the connections using prestressed carbon fiber-reinforced polymer (CFRP) rods. The proposed system consists of a mechanical wedge-barrel anchor to hold the prestressed CFRP rod and a clamping system to attach to the parent structure and to transmit forces via friction. A series of finite-element (FE) simulations was conducted to optimize the size and performance of the retrofit system. Laboratory static pull-off tests were conducted and different failure modes were studied and discussed. A novel test setup (with four supports) was designed for testing the steel connections. The effect of the geometrical imperfections during the installation of the connection was carefully investigated using the FE models and was verified through laboratory the tests. Laboratory fatigue tests were conducted on steel connections with the same dimensions as those in a railway bridge. The designed retrofit system was found to be capable of reducing the stresses at the angle connections by more than 40%. The results of the fatigue tests demonstrated that the designed system could survive more than 11  million load cycles without any fatigue damage or any indication of a loss in the CFRP prestressing level.
dc.publisherASCE
dc.titleDevelopment of Mechanical Strengthening System for Bridge Connections Using Prestressed CFRP Rods
dc.typeJournal Paper
dc.journal.volume147
dc.journal.issue3
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0002923
dc.journal.fristpage04020351-1
dc.journal.lastpage04020351-19
dc.page19
dc.treeJournal of Structural Engineering:;2021:;Volume ( 147 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record