Method of Reducing Energy Consumption for Heating Frost-Susceptible Soil around Chilled Underground Pipeline
Date
9/1/2020 1Author
E. V. Markov
S. A. Pulnikov
Y. S. Sysoev
N. V. Kazakova
Metadata
Show full item recordAbstract
This article is devoted to the calculation and optimization of the engineering protection of cold underground condensate pipelines using heat-tracing cable in frost-susceptible soils in Western Siberia. The method for stress–strain state calculation of a pipeline in frost-susceptible soils has been developed. The dependence of maximal stresses in the pipeline wall on the linear heat-generation rate of the heat-tracing cable in the case of a constant heating mode has been derived. The dependence shows a monotonic decrease of maximum displacement of the pipeline and stresses in the pipeline wall with an increase of the linear heat-generation rate. The influence of a startup delay of the heat-tracing cable to the stress–strain state of the pipeline has been numerically investigated. The use of heating mode with delayed startup reduces the electrical energy consumption by 35.4% for considered pipeline comparing a constant heating mode due to fast soil freezing around a pipeline at the initial stage. The effect of energy saving depends on the linear heat-generation rate of the heat-tracing cable. For the considered pipeline, heat-tracing cable with a minimum permissible linear heat-generation rate of 1 W · m−1 and 3.5 years startup delay provides maximum energy savings.