Show simple item record

dc.contributor.authorAli Etemadi
dc.contributor.authorCan Balkaya
dc.date.accessioned2022-01-30T21:26:23Z
dc.date.available2022-01-30T21:26:23Z
dc.date.issued10/1/2020 12:00:00 AM
dc.identifier.other%28ASCE%29CF.1943-5509.0001462.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4268202
dc.description.abstractA reinforced concrete building in Konya, Turkey, collapsed suddenly on February 2, 2004, and 92 residents died. This case study was performed to determine the alternate load paths and failure mechanism of the building. The essence of a forensic engineering investigation of a construction failure is to determine the failure mechanisms by using the procedural causes and contributing factors. The building behavior under the sudden loss of ground-story columns and various scenarios of column removal was assessed. The site works and stepwise nonlinear analysis were applied to get the failure mechanism of the collapsed building. The lessons learned from this case study forensic investigation are discussed, and the construction and project errors beneath the collapse are identified. Torsion is not a desired first mode of dynamic behavior. The progressive collapse of the RC building was the torsional mode. In building due to architectural needs, i.e., lack of the beam in exterior frames, discontinuities in the three-dimensional (3D) structural framing and very low bonds existed in the RC beams, resulting in an improper redistribution of the forces.
dc.publisherASCE
dc.titleCollapsed-RC Building Failure Mechanisms with a Forensic Engineering Approach
dc.typeJournal Paper
dc.journal.volume34
dc.journal.issue5
dc.journal.titleJournal of Performance of Constructed Facilities
dc.identifier.doi10.1061/(ASCE)CF.1943-5509.0001462
dc.page11
dc.treeJournal of Performance of Constructed Facilities:;2020:;Volume ( 034 ):;issue: 005
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record