dc.description.abstractThe need to improve the accuracy of mathematical models describing hydraulic networks (e.g., water distribution systems) poses numerous challenges regarding the problems of parameter calibration and optimal sampling. In this paper, a comparison is made between different sensor placing strategies, including a novel, direct (iteration-free) algorithm. The approach used is based on maximizing both the sensitivity and the so-called hydraulic distance of the sampling points without the need for optimization. Based on these sampled measurements, the pipe roughness coefficient of each pipe is calibrated individually (without grouping) by solving the resulting underdetermined linear system with singular value decomposition. The efficiency of the approach is demonstrated on case studies, including artificial (e.g., Anytown and C-town) and real-life water distribution systems through detailed statistical comparison.
dc.publisherASCE
dc.titleEfficient Technique for Pipe Roughness Calibration and Sensor Placement for Water Distribution Systems
dc.typeJournal Paper
dc.journal.volume146
dc.journal.issue1
dc.journal.titleJournal of Water Resources Planning and Management
dc.identifier.doi10.1061/(ASCE)WR.1943-5452.0001150
dc.page12
dc.treeJournal of Water Resources Planning and Management:;2020:;Volume ( 146 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record