Show simple item record

dc.contributor.authorWeiqiang Wang
dc.contributor.authorChengqing Wu
dc.contributor.authorZhongxian Liu
dc.contributor.authorKaixuan An
dc.contributor.authorJun-Jie Zeng
dc.date.accessioned2022-01-30T21:11:56Z
dc.date.available2022-01-30T21:11:56Z
dc.date.issued10/1/2020 12:00:00 AM
dc.identifier.other%28ASCE%29CC.1943-5614.0001057.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4267806
dc.description.abstractThe lateral impact behavior of hybrid fiber-reinforced polymer (FRP)-ultrahigh-performance concrete (UHPC)-steel double-skin tubular columns (DSTCs) was experimentally investigated in this study. Seven specimens, which had an outer diameter of 168 mm and a length of 2,000 mm, were tested under lateral impact loading. Different parameters, including the axial force level, impact energy, concrete type, void ratio, FRP tube thickness, and the presence/absence of the FRP tube, were investigated. The dynamic responses, including global/local damage modes, lateral deflection–time histories, impact force–time histories, strain–time histories, and acceleration–time histories, were investigated. The test results prove that the hybrid UHPC DSTCs exhibit very ductile behavior under lateral impact loading. The hybrid UHPC DSTCs have a higher lateral impact resistance capacity as compared to the hybrid DSTCs infilled with normal-strength concrete. The lateral impact resistance capacity of hybrid UHPC DSTCs with an applied axial force of 200 kN can be improved to some extent compared with those without any axial force. The impact energy, the void ratio, the FRP tube thickness, and the presence/absence of the FRP tube can significantly affect the lateral impact behavior of hybrid UHPC DSTCs. Furthermore, the lateral impact behaviors of hybrid DSTCs, concrete-filled double-skin steel tubes (CFDSTs), and concrete-filled steel tubes (CFSTs) were compared and discussed based on the experimental results in this study as well as in other literature studies.
dc.publisherASCE
dc.titleExperimental Investigation of the Hybrid FRP-UHPC-Steel Double-Skin Tubular Columns under Lateral Impact Loading
dc.typeJournal Paper
dc.journal.volume24
dc.journal.issue5
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/(ASCE)CC.1943-5614.0001057
dc.page15
dc.treeJournal of Composites for Construction:;2020:;Volume ( 024 ):;issue: 005
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record