Show simple item record

dc.contributor.authorBrahim Benmokrane
dc.contributor.authorVicki L. Brown
dc.contributor.authorAhmed H. Ali
dc.contributor.authorKhaled Mohamed
dc.contributor.authorCarol Shield
dc.date.accessioned2022-01-30T21:05:31Z
dc.date.available2022-01-30T21:05:31Z
dc.date.issued8/1/2020 12:00:00 AM
dc.identifier.other%28ASCE%29CC.1943-5614.0001040.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4267639
dc.description.abstractDesign guides for fibre-reinforced polymer-reinforced concrete (FRP-RC) require that the design tensile strength of FRP bars be determined by multiplying the guaranteed tensile strength by an environmental reduction factor (CE), to account for the long-term effects of environmental exposure. The recommended CE values in the American Concrete Institute (ACI) design guide are based on a consensus of the opinion of ACI 440 Committee members and believed to be conservative. The ACI design guide notes the expectation that, with continued research, CE values will become more reflective of observed environmental performance. In this study, CE values were estimated for a compiled database of glass FRP (GFRP) bars based on short-term results from accelerated aging tests. The CE values were calculated with a prediction model considering the effects of seasonal temperature fluctuations, service year, and relative humidity (RH) of exposure. The analysis shows that the calculated values of CE depend to a certain extent on the mean annual temperatures and RH. In all cases, however, the calculated values were higher than those recommended in the ACI design guide. The authors recommend a CE value of 0.85 for an assumed service life of 75–100 years to be applied to the guaranteed tensile strength as the basis for determining the design tensile strength. This value is recommended for GFRP bars complying with ASTM Standards, whether exposed or unexposed to earth and weather in cold temperatures and climates encountered in most regions of the world.
dc.publisherASCE
dc.titleReconsideration of the Environmental Reduction Factor <i>C<sub>E</sub></i> for GFRP Reinforcing Bars in Concrete Structures
dc.typeJournal Paper
dc.journal.volume24
dc.journal.issue4
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/(ASCE)CC.1943-5614.0001040
dc.page6
dc.treeJournal of Composites for Construction:;2020:;Volume ( 024 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record