Show simple item record

dc.contributor.authorWei Zeng
dc.contributor.authorJinzhe Gong
dc.contributor.authorPeter R. Cook
dc.contributor.authorJohn W. Arkwright
dc.contributor.authorAngus R. Simpson
dc.contributor.authorBenjamin S. Cazzolato
dc.contributor.authorAaron C. Zecchin
dc.contributor.authorMartin F. Lambert
dc.date.accessioned2022-01-30T20:39:46Z
dc.date.available2022-01-30T20:39:46Z
dc.date.issued10/1/2020 12:00:00 AM
dc.identifier.other%28ASCE%29HY.1943-7900.0001812.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4266900
dc.description.abstractLeak detection is crucial in reducing water loss and improving the efficiency of water transmission in water distribution systems. A hydraulic transient paired-IRF (impulse response function) technique previously developed was demonstrated as an effective method for leak detection. However, the technique requires transient pressure measurements at two locations in close proximity in the pipe, which is often very difficult to achieve for buried pipelines using conventional flush-mounted pressure transducers. The current paper reports on the use of a customized in-pipe optical fiber sensor array for transient pressure measurement and the implementation of the paired-IRF technique for leak detection in a laboratory copper pipeline. The in-pipe optical fiber sensor array contains two fiber Bragg grating (FBG) pressure sensors contained in a protective cable. It is inserted into the laboratory pipeline through a tapping point to measure the pressure responses induced by a voice-coil pressure wave generator, which generates a persistent excitation. The paired-IRF technique is then applied to the measurements to obtain the paired-IRF of the pipe system. The paired-IRF is determined and clearly indicates the existence of the simulated leak (through a side discharge on the pipe). In addition, a pipe joint is detected using the paired-IRF trace, which confirms that the detection system and method have the ability to achieve high detectability. The successful experimental application illustrates that the in-pipe optical fiber sensor array can be applied in pipes with limited access points and leak detection can be achieved by combining with the paired-IRF technique.
dc.publisherASCE
dc.titleLeak Detection for Pipelines Using In-Pipe Optical Fiber Pressure Sensors and a Paired-IRF Technique
dc.typeJournal Paper
dc.journal.volume146
dc.journal.issue10
dc.journal.titleJournal of Hydraulic Engineering
dc.identifier.doi10.1061/(ASCE)HY.1943-7900.0001812
dc.page6
dc.treeJournal of Hydraulic Engineering:;2020:;Volume ( 146 ):;issue: 010
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record