    Behavior and Limit States of Long-Span Composite Floor Beams with Simple Shear Connections Subject to Compartment Fires: Experimental Evaluation

    Thumbnail
    View/Open
    %28ASCE%29ST.1943-541X.0002627.pdf (2.739Mb)
    Date
    2020
    Author
    Lisa Choe
    Selvarajah Ramesh
    William Grosshandler
    Matthew Hoehler
    Mina Seif
    John Gross
    Matthew Bundy
    Metadata
    Show full item record
    Abstract
    This paper presents the results of compartment fire experiments on four 12.8-m-long composite floor beams with various end support conditions. Specimens were constructed as partially composite beams, consisting of W18×35 steel beams and 83-mm-thick lightweight concrete slabs cast on top of 76-mm-deep ribbed steel deck units. Test variables included two types of simple shear connections (shear-tab and welded-bolted double-angle connections) and the presence or absence of slab continuity over the girders. Each specimen was subjected to gravity loading using hydraulic actuators and 4,000-kW compartment fires produced using natural gas–fueled burners. This study evaluated the characteristics of the fire loading and thermal and structural responses of the specimens. The test results indicated that there were significant effects of thermal restraints on the behavior and failure modes of the specimens with simple shear connections. The specimens resisted gravity loads at large vertical displacements near midspan (approximately a ratio of span length over 20) under fire loading. However, various limit states and vulnerabilities to fires were observed, including local buckling of steel beams near supports, flexural failure (yielding of steel beams and concrete fracture near restrained end supports), and connection failure (weld shear or bolt shear) during heating and cooling, which could lead to partial or total collapse of the floor system.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4266667
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV