• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Behavior of CFSC-Encased Shear Connectors in Steel-Concrete Joints: Push-Out Tests

    Thumbnail
    View/Open
    %28ASCE%29ST.1943-541X.0002577.pdf (3.079Mb)
    Date
    2020
    Author
    Shaohua He
    Zhi Fang
    Ayman S. Mosallam
    Yi Ouyang
    Chao Zou
    Metadata
    Show full item record
    Abstract
    A concrete-filled steel cell (CFSC) is commonly used in steel-concrete joints of hybrid girders. The performance of shear connectors embedded in CFSCs has been investigated in the current study in which a series of push-out tests were performed in order to assess the mechanical behavior of a perfobond strip connector (PBL) and headed steel studs. The failure modes, load-slip relations, load-strain relations, and the influence of the push-out test arrangement on such behaviors are presented and discussed in this study. Comparisons between the current experimental results and those presented in previous studies by the authors demonstrate that the average peak bond and residual bond strength at the interface between the perforated steel plate and the concrete in CFSC are 1.0 and 1.4 times higher than those derived from the plug-in type of push-out specimens (PI type), respectively. Moreover, it is found that the steel cell confinement has little impact on the performance of the transverse steel rebars of the PBL and the behavior of steel studs. Because the confinement provided by the steel cell is able to improve the shear capacity of the concrete dowel in the PBL, the ultimate shear capacity of the PBL encased in CFSC is 31% higher than that of the PBL without confinement. It is also discovered that the ultimate strengths of the PBL and the steel studs fabricated in CFSC could not be reached at the same time. Furthermore, the experimental results are compared to the shear resistances predicted by the available analytical equations for the PBLs without confinements. It is found that the ultimate shear resistances of the PBLs under the confinement are underestimated by the existing equations.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4266610
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV