    Damage Threshold of Near-Cross-Ply Tubes Used in Concrete-Filled FRP Tubes Loaded in Flexure

    Thumbnail
    View/Open
    %28ASCE%29CC.1943-5614.0000990.pdf (2.455Mb)
    Date
    2020
    Author
    Chenxi Lu
    James St. Onge
    Amir Fam
    Metadata
    Show full item record
    Abstract
    Concrete-filled fiber-reinforced polymer (FRP) tubes (CFFTs) have been studied extensively, but a lingering question remains regarding the vulnerability of the exposed tube to accidental damage or vandalism. In this paper, the effect of damage induced in the tubes on the flexural strength of CFFTs is studied. A total of 18 specimens with tubes having nearly orthogonal fiber arrangements were tested in four-point bending, including one undamaged control specimen to establish its full nominal strength (Mno). A total of 11 specimens with artificially induced damage in the form of through-thickness cuts on the tension side, and six with cuts on the compression side at midspan were also tested. Longitudinal, circumferential, and square cuts were introduced. Cut length and proximity to neutral axis were varied. It is shown that the most critical cut is the circumferential one on extreme tension. A sharp decline occurred initially in the nominal residual strength ratio (Mn/Mno), from 1.0 to 0.55 at a cut length-to-perimeter ratio of 0.02πD, followed by a much less steep trend up to Mn/Mno of 0.25 at a 0.2πD cut. As the location of a 0.03πD circumferential cut shifted from extreme tension to an 80° from the bottom, Mn/Mno increased from 0.52 to 1.0. A longitudinal cut of 0.1πD on the tension side resulted in Mn/Mno of 0.69 as opposed to 0.38 for the circumferential cut. Compression side longitudinal and circumferential cuts were less critical with Mn/Mno of 0.8 to 0.9. For practical design, a case study based on ultimate static strength showed that the CFFT can tolerate a circumferential tension cut of up to 0.29πD before it has to be taken out of service.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4266297
    Collections
    • Journal of Composites for Construction

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV