• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Environmental Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Environmental Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Removal Kinetics of Olive-Mill Wastewater in a Batch-Operated Aerobic Bioreactor

    Thumbnail
    View/Open
    %28ASCE%29EE.1943-7870.0001654.pdf (792.7Kb)
    Date
    2020
    Author
    Sinan Kul
    Alper Nuhoğlu
    Metadata
    Show full item record
    Abstract
    This study involves the removal of the olive-mill wastewater (OMW), which is a significant pollutant, in a batch reactor under aerobic conditions by mixed cultures. It also includes comparison of different substrate inhibition models, calculation of kinetic parameters, and testing the merit of the chosen mathematical model with respect to OMW concentration and changes with time. Average initial microorganism concentration (X0) in the batch reactor was 100±15  mg L−1. During the study the treatment of OMW with initial chemical oxygen demand (S0) concentration between 10 and 1,000  mg COD L−1 was investigated. Maximum specific growth rate (μmax) was reached with 130  mg COD L−1 initial concentration and 3 h experimental duration produced 57.17% chemical oxygen demand (COD) removal efficiency. Other experiments with increasing initial concentration increased COD removal duration, with 927  mg COD L−1 initial concentration regressing to 8.88% removal efficiency after 3 h. The biokinetic equations of Aiba, Haldane, Tseng, and Yano and Koga were chosen to relate S0 concentration to specific growth rate (μ) and the biokinetic parameters in these equations were calculated. The most appropriate biokinetic equation was the Haldane model in terms of R2 value and the Haldane equation parameters 0.43  h−1, 45.34  mg L−1, and 207.97  mg L−1 were calculated for μmax, half-saturation constant (Ks) and inhibition constant (Ki), respectively. Also, a mathematical biokinetic model including the Haldane equation was used to test the OMW removal performance and it was seen that the chosen model was well able to reflect system behavior. After the calibration of μmax, the most-sensitive parameter of the Haldane model, to 0.22  h−1, the model gave a better fit for all tested conditions.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4265333
    Collections
    • Journal of Environmental Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV