• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Environmental Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Environmental Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Continuous Fixed-Bed Adsorption of Heavy Metals Using Biodegradable Adsorbent: Modeling and Experimental Study

    Thumbnail
    View/Open
    %28ASCE%29EE.1943-7870.0001636.pdf (1.610Mb)
    Date
    2020
    Author
    Renu
    Madhu Agarwal
    Kailash Singh
    Ragini Gupta
    R. K. Dohare
    Metadata
    Show full item record
    Abstract
    In this study, a continuous fixed-bed column was investigated for heavy metal removal using modified wheat bran as adsorbent. Clay and chitosan were used as binders with the adsorbent to prepare adsorbent pellets in a 1∶1∶3 (clay∶chitosan∶adsorbent) ratio by weight. Clay and chitosan provide adhesiveness and mechanical strength to the pellet. The scanning electron microscopy analysis–energy dispersive X-ray spectroscopy (SEM-EDS) analysis confirms the adsorption of copper, chromium, and cadmium in the adsorbent pellet. The fixed bed was operated at a pH of 6 and temperature of 35°C for heavy metal removal. A mathematical model was prepared for continuous column and then experiments were carried out with various parameters such as bed height (0.15–0.45 m), initial concentration (100–500  mg/L), and flow rate (5–15  mL/min). The removal order for heavy metals follows Cr>Cu>Cd. The optimum conditions obtained were a flow rate 5  mL/min, bed height of 0.45 m, and initial concentration of 100  mg/L. The breakthrough curve obtained from experimental data was compared with the curve obtained from the model. It was found that the prepared adsorbent pellets were efficient at removing heavy metals. The developed mathematical model could predict column behavior with desirable accuracy. Further, high R2, low chi-squared, and mean absolute percentage error (MAPE) values of up to 0.999, 0.025%, and 0.378%, respectively, indicate that model and experimental data were well fitted.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4265316
    Collections
    • Journal of Environmental Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV