    Experimental Behavior of Pretensioned Bent Caps with Internal Voids for Weight Reduction

    Thumbnail
    View/Open
    %28ASCE%29BE.1943-5592.0001410.pdf (1.112Mb)
    Date
    2020
    Author
    Codi D. McKee
    Ju Dong Lee
    Anna C. Birely
    John B. Mander
    Metadata
    Show full item record
    Abstract
    Precast bent caps offer the opportunity to reduce onsite labor and materials and to accelerate the speed of construction. For many bridges, the weight is manageable for shipping and placement without the need for large cranes. For large bent caps, the weight can become a significant challenge for construction. Internal voids can be effective in reducing the weight but introduce the potential for the formation of shear cracks at service loads, because the shear width is smaller than in a solid bent cap. Internal voids are an attractive option when bent caps are pretensioned, because pretensioning delays the formation of cracks. This paper presents the results of a full-scale experimental test program that investigated the progression of damage and the failure mechanisms of pretensioned bent caps with internal voids. Test specimens were subassemblies of a portion of a multicolumn bent that included an overhang, a negative bending region at the connection to a column, and a positive bending region. The variables investigated were the presence of a void, the amount of prestressing, and the void termination location. Results indicated that voided caps had similar flexural behavior to solid caps, but were more prone to shear cracking and had more brittle failures. The use of a higher prestressing force was found to significantly delay flexural cracking but to have a minor effect on delaying the formation of shear cracks. The location of void termination adjacent to the connection region influenced the extent of the damage at failure.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4264788
    Collections
    • Journal of Bridge Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV