Show simple item record

dc.contributor.authorLesley H. Sneed
dc.contributor.authorGiulia Baietti
dc.contributor.authorGiacomo Fraioli
dc.contributor.authorChristian Carloni
dc.date.accessioned2019-09-18T10:40:09Z
dc.date.available2019-09-18T10:40:09Z
dc.date.issued2019
dc.identifier.other%28ASCE%29CC.1943-5614.0000963.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4260046
dc.description.abstractIn this study, a new type of composite comprised of steel cords embedded in a mortar matrix—referred to as steel-reinforced grout (SRG)—is explored for use in the confinement of masonry columns. This paper presents the results of an experimental study carried out to understand the behavior of solid clay brick masonry columns confined by single-layer SRG jackets. Thirty-one confined and three unconfined columns with a square cross-section were tested to failure under a monotonic concentric compressive load. Test parameters considered were the SRG matrix type, column corner condition, and steel cord sheet density (i.e., steel cord spacing) in the SRG jacket. SRG confinement improved the compressive strength, ultimate strain, and energy absorption of masonry columns relative to the unconfined condition. Models from the literature for FRP-confined masonry were examined for their applicability to predict the strength increase from the SRG jacket, with certain models predicting the confined compressive strength within 9% of the test values.
dc.publisherAmerican Society of Civil Engineers
dc.titleCompressive Behavior of Brick Masonry Columns Confined with Steel-Reinforced Grout Jackets
dc.typeJournal Paper
dc.journal.volume23
dc.journal.issue5
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/(ASCE)CC.1943-5614.0000963
dc.page04019037
dc.treeJournal of Composites for Construction:;2019:;Volume ( 023 ):;issue: 005
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record