• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Bridge Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Bridge Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Experimental and Analytical Investigation on Pull-Out Performance of Multihole Thin-Rib Perfobond Connectors

    Thumbnail
    View/Open
    %28ASCE%29BE.1943-5592.0001400.pdf (3.442Mb)
    Date
    2019
    Author
    Yao-Yu Zhu
    Xin Nie
    Jian-Sheng Fan
    Bing Cui
    Li-Ji Huang
    Metadata
    Show full item record
    Abstract
    Perfobond connectors are commonly used to transfer the shear force with the transverse bar sheared off as the failure mode in steel–concrete composite structures. However, the perfobond connectors used to prevent the steel–concrete interface from separating in composite structures with load bearing steel bars that cannot be sheared off urgently need to be studied. Experimental and analytical studies were conducted to develop a novel thin-rib perfobond connector used in steel–concrete composite bridge towers. Based on the load characteristics of the Nanjing No. 5 Yangtze River Bridge tower, which is the first double-steel–plate concrete composite cable-stayed bridge tower in the world, the pull-out performance of the perfobond connectors in the large-scale composite tower were studied. Thin ribs were adopted in the connectors to avoid shearing off the longitudinal steel bars during the pull-out process. The coupling pull-out performance between adjacent perfobond connectors was investigated to demonstrate the performance differences between the multihole and the single-hole thin-rib perfobond connectors. The effects of the plate thickness, the distance from hole edge to rib bottom, the distance from hole edge to rib side, the hole diameter, the transverse bar diameter, and the transverse bar position in the connector hole were examined based on the experiments of 24 single-hole specimens and 24 trihole specimens. All stages of the load-displacement curves were calibrated, and the strain history of the steel parts was discussed. The main failure mode observed from the pull-out tests was steel plate fracture. Failure mechanism analysis showed that the position of the transverse bar in the hole affected the bearing capacity, stiffness, and ductility of the connector. Considering the effect of hole numbers, the hole-side part of a multihole thin-rib perfobond connector was relatively strengthened. An analytical model and calculation formulas to predict the pull-out capacity of the thin-rib perfobond connectors were further established, and the proposed method was found to be in good agreement with the experimental results, offering theoretical guidance for engineering practice.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4259969
    Collections
    • Journal of Bridge Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV