Show simple item record

dc.contributor.authorMei-ni Su
dc.contributor.authorLiangliang Wei
dc.contributor.authorJi-Hua Zhu
dc.contributor.authorTamon Ueda
dc.contributor.authorGuan-ping Guo
dc.contributor.authorFeng Xing
dc.date.accessioned2019-09-18T10:38:33Z
dc.date.available2019-09-18T10:38:33Z
dc.date.issued2019
dc.identifier.other%28ASCE%29CC.1943-5614.0000949.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4259715
dc.description.abstractThis study introduces the use of the combined impressed current cathodic protection–structural strengthening (ICCP-SS) as a technique for repairing reinforced concrete structures that have been subjected to chloride-induced corrosion. The development of this technique is based on the combination of a carbon-fiber mesh (CF-MESH) and a polymer-modified cementitious matrix to produce a carbon-fiber-reinforced cementitious matrix (C-FRCM). First, the effects of different types and amounts of high molecular weight polymer and short chopped carbon fibers on the flexural and compressive strength, conductivity, and shear strength of a matrix with concrete substrate were investigated in order to find the optimum ingredients required for a high-performance cementitious matrix. Second, a shaped CF-MESH was bonded onto the surface of a concrete cube using the aforementioned optimized cementitious matrix. The impressed current cathodic protection (ICCP) technique was then applied to the specimens by using different current densities with the CF-MESH as the anode. During the protection period, the protection conditions of rebars subjected to ICCP were assessed by analyzing a variety of electrochemical parameters. Third, single shear tests were conducted, and the shear strengths and failure modes of the specimens were obtained and compared in order to evaluate the effects of the ICCP on shear stress transfer. The results show that the proposed technique based on the newly proposed C-FRCM composite is able to provide effective cathodic protection as well as shear stress transfer behavior to RC structures subjected to chloride-induced corrosion, leading to an improvement with respect to structural durability.
dc.publisherAmerican Society of Civil Engineers
dc.titleCombined Impressed Current Cathodic Protection and FRCM Strengthening for Corrosion-Prone Concrete Structures
dc.typeJournal Paper
dc.journal.volume23
dc.journal.issue4
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/(ASCE)CC.1943-5614.0000949
dc.page04019021
dc.treeJournal of Composites for Construction:;2019:;Volume ( 023 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record