Show simple item record

dc.contributor.authorAlsagri, Ali Sulaiman
dc.contributor.authorChiasson, Andrew
dc.contributor.authorGadalla, Mohamed
dc.date.accessioned2019-09-18T09:08:19Z
dc.date.available2019-09-18T09:08:19Z
dc.date.copyright4/24/2019 12:00:00 AM
dc.date.issued2019
dc.identifier.issn0199-6231
dc.identifier.othersol_141_5_051006
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4259303
dc.description.abstractThe aim of this study was to conduct thermodynamic and economic analyses of a concentrated solar power (CSP) plant to drive a supercritical CO2 recompression Brayton cycle. The objectives were to assess the system viability in a location of moderate-to-high-temperature solar availability to sCO2 power block during the day and to investigate the role of thermal energy storage with 4, 8, 12, and 16 h of storage to increase the solar share and the yearly energy generating capacity. A case study of system optimization and evaluation is presented in a city in Saudi Arabia (Riyadh). To achieve the highest energy production per unit cost, the heliostat geometry field design integrated with a sCO2 Brayton cycle with a molten-salt thermal energy storage (TES) dispatch system and the corresponding operating parameters are optimized. A solar power tower (SPT) is a type of CSP system that is of particular interest in this research because it can operate at relatively high temperatures. The present SPT-TES field comprises of heliostat field mirrors, a solar tower, a receiver, heat exchangers, and two molten-salt TES tanks. The main thermoeconomic indicators are the capacity factor and the levelized cost of electricity (LCOE). The research findings indicate that SPT-TES with a supercritical CO2 power cycle is economically viable with 12 h thermal storage using molten salt. The results also show that integrating 12 h-TES with an SPT has a high positive impact on the capacity factor of 60% at the optimum LCOE of $0.1078/kW h.
dc.publisherAmerican Society of Mechanical Engineers (ASME)
dc.titleViability Assessment of a Concentrated Solar Power Tower With a Supercritical CO2 Brayton Cycle Power Plant
dc.typeJournal Paper
dc.journal.volume141
dc.journal.issue5
dc.journal.titleJournal of Solar Energy Engineering
dc.identifier.doi10.1115/1.4043515
dc.journal.fristpage51006
dc.journal.lastpage051006-15
dc.treeJournal of Solar Energy Engineering:;2019:;volume( 141 ):;issue: 005
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record