• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Engineering and Science in Medical Diagnostics and Therapy
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Engineering and Science in Medical Diagnostics and Therapy
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Design of a Metered-Dose Inhaler Actuated by Shape Memory Alloy

    Thumbnail
    View/Open
    jesmdt_002_03_031003.pdf (1.401Mb)
    Date
    2019
    Author
    Utter, Brent
    Metadata
    Show full item record
    Abstract
    The global prevalence of asthma and chronic obstructive pulmonary disease (COPD) is on the order of hundreds of millions of individuals. The most common treatment approach is to take a self-administered inhaled medication. This study focuses on pressurized metered-dose inhalers (MDIs) where, unfortunately, rates of mishandling and misuse are extremely high and lead to improper treatment. One significant challenge results from the timing miscoordination of the medicine dispersion and inhalation breath. To address this, this study demonstrates the feasibility of automating the timing of the medicine dispersion by integrating a shape memory alloy (SMA) actuator and a differential pressure sensor into the casing of a traditional MDI. The approach is to measure the vacuum pressure created by an inspiratory breath, evaluate criteria indicating an acceptable breath, and if those criteria are met, heat the SMA actuator to depress the cartridge and disperse medicine. To meet actuation requirements and reliably depress the inhaler cartridge, two concepts for configuring an SMA wire were designed and compared with respect to complexity, actuation timing, and energy consumption. The proposed concept was able to disperse medicine in 263 ms, averaged over 100 actuations on a single battery charge, facilitating the early dispersion of medicine during an inhalation breath. By describing the design process of an SMA-actuated MDI that does not result in a significant increase of its weight or size, this study provides a practical technological approach for reducing the improper treatment of asthma and COPD due to timing miscoordination.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4259176
    Collections
    • Journal of Engineering and Science in Medical Diagnostics and Therapy

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV