Show simple item record

dc.contributor.authorCzakoj, Tomáš
dc.contributor.authorLosa, Evžen
dc.date.accessioned2019-09-18T09:05:34Z
dc.date.available2019-09-18T09:05:34Z
dc.date.copyright4/16/2019 12:00:00 AM
dc.date.issued2019
dc.identifier.issn2332-8983
dc.identifier.otherners_005_03_030903
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4258763
dc.description.abstractThree-dimensional Monte Carlo code KENO-VI of SCALE-6.2.2 code system was applied for criticality calculation of the LR-0 reactor core. A central module placed in the center of the core was filled by graphite, lithium fluoride-beryllium fluoride (FLIBE), and lithium fluoride-sodium fluoride (FLINA) compounds. The multiplication factor was obtained for all cases using both ENDF/B-VII.0 and ENDF/B-VII.1 nuclear data libraries. Obtained results were compared with benchmark calculations in the MCNP6 using ENDF/B-VII.0 library. The results of KENO-VI calculations are found to be in good agreement with results obtained by the MCNP6. The discrepancies are typically within tens of pcm excluding the case with the FLINA filling. Sensitivities and uncertainties of the reference case with no filling were determined by a continuos-energy version of the TSUNAMI sequence of SCALE-6.2.2. The obtained uncertainty in multiplication factor due to the uncertainties in nuclear data is about 650 pcm with ENDF/B-VII.1.
dc.publisherAmerican Society of Mechanical Engineers (ASME)
dc.titleCriticality Calculations and Basic Sensitivity/Uncertainty Investigation of LR-0 Benchmark Core
dc.typeJournal Paper
dc.journal.volume5
dc.journal.issue3
dc.journal.titleJournal of Nuclear Engineering and Radiation Science
dc.identifier.doi10.1115/1.4041692
dc.journal.fristpage30903
dc.journal.lastpage030903-5
dc.treeJournal of Nuclear Engineering and Radiation Science:;2019:;volume( 005 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record