    A Two-Stage Local Positioning Method With Misalignment Calibration for Robotic Structural Monitoring of Buildings

    Thumbnail
    View/Open
    ds_141_06_061014.pdf (1.736Mb)
    Date
    2019
    Author
    Wang, Rong
    Xiong, Zhi
    Chen, Yulu Luke
    Manjunatha, Preetham
    Masri, Sami F.
    Metadata
    Show full item record
    Abstract
    In structural health monitoring (SHM) applications carried out by mobile robots, the precise locating of the SHM robot is essential for accurate detection and quantification of defects. The traditional dead reckoning (DR) approach can only provide local position in the horizon, which is not enough for SHM applications in three dimensions in large buildings. In this paper, a new robot positioning algorithm for active building structural defect detection and localization is proposed. The two-stage robot positioning scheme is designed through the self-misalignment calibration and the positioning during SHM task stages, fusing the absolute and relative measurements. In order to overcome the drawback of the DR algorithm, in the full analysis of existing localization mode that can be applied to mobile robots, this paper adopted the inertial navigation system (INS) approach to measure the absolute motion information of a moving robot. On this basis, through the transformation between the absolute positioning coordinates and the local positioning coordinates of buildings, the mobile robot's optimal trajectory on building surface was designed for self-calibration of coordinate misalignments. The proposed method could effectively achieve the robot local positioning in building coordinate frame by fusing the external relative assistant measurements with absolute measurement. By using the designed strategies, the coordinate misalignment can also be self-calibrated effectively, improving local positioning accuracy.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4258523
    Collections
    • Journal of Dynamic Systems, Measurement, and Control

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV