Show simple item record

dc.contributor.authorVieira, Gabriela C.
dc.contributor.authorFlórez M, Juan Pablo
dc.contributor.authorMantelli, Marcia B. H.
dc.date.accessioned2019-09-18T09:03:39Z
dc.date.available2019-09-18T09:03:39Z
dc.date.copyright7/31/2019 12:00:00 AM
dc.date.issued2019
dc.identifier.issn0022-1481
dc.identifier.otherht_141_09_091812
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4258385
dc.description.abstractThis work presents experimental studies of a two-phase loop thermosyphon, designed to use the aircraft fuselage low temperatures at high altitude to promote passive thermal management of electronics components in avionics. The main purpose of this work is to develop the evaporator of a loop thermosyphon composed of one evaporator coupled to two condensers presented in the literature. The proposed evaporator comprises ten square stacked copper plates bonded by diffusion. Channels were manufactured in the inner plates so that internal grooves are obtained after the stack is bonded. Studies with concentrated and distributed heat sources over the evaporator external surface are under performance. Parameters such as start-up and operation temperatures will be compared, according to the condition submitted.
dc.publisherAmerican Society of Mechanical Engineers (ASME)
dc.titleStudy of a Loop Thermosyphon Evaporator for Thermal Control of Aircrafts
dc.typeJournal Paper
dc.journal.volume141
dc.journal.issue9
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4044277
dc.journal.fristpage91812
dc.treeJournal of Heat Transfer:;2019:;volume( 141 ):;issue: 009
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record