Show simple item record

dc.contributor.authorJoung, Wukchul
dc.contributor.authorLee, Joohyun
dc.date.accessioned2019-09-18T09:02:44Z
dc.date.available2019-09-18T09:02:44Z
dc.date.copyright7/22/2019 12:00:00 AM
dc.date.issued2019
dc.identifier.issn0022-1481
dc.identifier.otherht_141_09_091805
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4258214
dc.description.abstractRecently, a novel temperature control technique utilizing the unique thermohydraulic operating principles of the pressure-controlled loop heat pipes (PCLHPs) was proposed and proved its effectiveness, by which a faster and more stable temperature control was possible by means of the pressure control. However, due to its recent emergence, the proposed hydraulic temperature control technique has not been fully characterized in terms of the various operating parameters including the sink temperature. In this work, the effect of the sink temperature on the loop heat pipe (LHP)-based hydraulic temperature control was investigated to improve the stability of the proposed technique. Start-up characteristics and transient responses of the operating temperatures to different pressure steps and sink temperatures were examined. From the test results, it was found that there was a minimum sink temperature, which ensured a steady-state operation after the start-up and a stable hydraulic temperature control with the increasing pressure steps, due to the unstable balance between the heat leak and the liquid subcooling in the compensation chamber at low sink temperatures. In addition, the range of the stable hydraulic temperature control was extended with the increasing coolant temperature due to the decreased heat leak, which resulted in the increased pressure difference between the evaporator and the compensation chamber. Therefore, it was found and suggested that for a stable hydraulic temperature control in an extended range, it was necessary to operate the PCLHP at higher sink temperatures than the low limit.
dc.publisherAmerican Society of Mechanical Engineers (ASME)
dc.titleEffect of Sink Temperature on the Stability of the Pressure-Controlled Loop Heat Pipe
dc.typeJournal Paper
dc.journal.volume141
dc.journal.issue9
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4043956
dc.journal.fristpage91805
dc.journal.lastpage091805-8
dc.treeJournal of Heat Transfer:;2019:;volume( 141 ):;issue: 009
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record