Show simple item record

dc.contributor.authorWu, Mengli
dc.contributor.authorNie, Qi
dc.contributor.authorLi, Yunpeng
dc.contributor.authorYue, Xianqu
dc.contributor.authorChen, Weibin
dc.contributor.authorWang, Chiyu
dc.date.accessioned2019-09-18T09:02:17Z
dc.date.available2019-09-18T09:02:17Z
dc.date.copyright6/12/2019 12:00:00 AM
dc.date.issued2019
dc.identifier.issn0022-1481
dc.identifier.otherht_141_08_081901
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4258126
dc.description.abstractIn order to ensure flight safety in cold winter, aircraft ground deicing is crucial and necessary. In Chinese deicing fluid heating system, the helically coiled tube is paramount exchanger to heat deicing fluid. The deicing fluid is ethylene-glycol-based mixture with high viscosity. Aiming at heat transfer enhancement of deicing fluid, ring rib is formed by an embossed tube wall toward the internal of the tube; thus, transversely corrugated helically coiled tube (TCHC) is achieved. Depth and width are two key geometrical parameters of ring rib. Based on field synergy principle, the influence of depth–diameter ratio (H/D) and width-diameter ratio (w/D) is investigated through numerical simulation. The results show that outlet temperature, mean convection heat transfer coefficient, and Nusselt number have similar trends, which first increase and then decrease nonlinearly. The variation of flow resistance coefficient is inversely proportional to Reynolds number. Especially, the effect of H/D is more significant than that of w/D. Field synergy angle and velocity field are also analyzed to reveal the mechanism of heat transfer. TCHC performs better than the original tube. Orthogonal experiment calculates the outlet temperature of TCHC when H/D and w/D change. The combination of H/D=0.075 and w/D=0.5 is best solution. TCHC effectively enhances heat transfer of deicing fluid. Therefore, TCHC is beneficial to improve the deicing efficiency and ensure the flight punctuality.
dc.publisherAmerican Society of Mechanical Engineers (ASME)
dc.titleInfluence of Geometrical Parameters on Heat Transfer of Transversely Corrugated Helically Coiled Tube for Deicing Fluid
dc.typeJournal Paper
dc.journal.volume141
dc.journal.issue8
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4043835
dc.journal.fristpage81901
dc.journal.lastpage081901-11
dc.treeJournal of Heat Transfer:;2019:;volume( 141 ):;issue: 008
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)