Show simple item record

dc.contributor.authorKumar, Bipin
dc.contributor.authorPatil, Anil Kumar
dc.contributor.authorJain, Siddharth
dc.contributor.authorKumar, Manoj
dc.date.accessioned2019-09-18T09:01:54Z
dc.date.available2019-09-18T09:01:54Z
dc.date.copyright6/12/2019 12:00:00 AM
dc.date.issued2019
dc.identifier.issn0022-1481
dc.identifier.otherht_141_08_081801
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4258059
dc.description.abstractThe present work deals with the study of entropy generation in circular tube fitted with perforated twisted tape (PTT) insert with multiple V cuts. Experimental data pertaining to heat transfer and frictional losses are collected for solid twisted tape (STT), PTT, double V cut PTT, and PTT with multiple V cuts by varying the twist ratio in the range of 2–6 for the Reynolds number range of 2000–25,000. The entropy generation rate of heated tube with insert is found to be less than the smooth tube in most of the cases under similar operating conditions. The minimum value of entropy generation number corresponds to the PTT having twist ratio of 3.
dc.publisherAmerican Society of Mechanical Engineers (ASME)
dc.titleStudy of Entropy Generation in Heat Exchanger Tube With Multiple V Cuts in Perforated Twisted Tape Insert
dc.typeJournal Paper
dc.journal.volume141
dc.journal.issue8
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4043769
dc.journal.fristpage81801
dc.journal.lastpage081801-8
dc.treeJournal of Heat Transfer:;2019:;volume( 141 ):;issue: 008
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record