Show simple item record

dc.contributor.authorChauhan, Manish
dc.contributor.authorDeshpande, Nikhil
dc.contributor.authorCaldwell, Darwin G.
dc.contributor.authorMattos, Leonardo S.
dc.date.accessioned2019-06-08T09:28:56Z
dc.date.available2019-06-08T09:28:56Z
dc.date.copyright4/4/2019 12:00:00 AM
dc.date.issued2019
dc.identifier.issn1932-6181
dc.identifier.othermed_013_02_021006.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4257637
dc.description.abstractTrans-oral laser microsurgery (TLM) is a surgical procedure for removing malignancies (e.g., cysts, polyps, tumors) of the laryngeal region through laser ablation. Intraoperative microsurgical forceps (i.e., microforceps) are used for tissue manipulation. The microforceps are rigid, single degree-of-freedom (DOF) devices (open–close) with precurved jaws to access different parts of the curved cylindrical laryngeal region. These microforceps are manually handled and are subject to hand tremors, poor reachability, and nonergonomic use, resulting in poor efficacy and efficiency in the surgery. A novel 3DOF motorized microforceps device is presented here, integrated with a 6DOF serial robotic manipulator. The device, referred to as RMF-3, offers three motorized DOFs: (i) open–close forceps jaw; (ii) tool rotation; and (iii) tool-tip articulation. It is designed to be compliant with TLM spatial constraints. The manual handling is replaced by tele-operation device, the omega.7. The design of the RMF-3 is characterized through theoretical and experimental analysis. The device shows a maximum articulation of 38 deg and tool rotation of 100 deg. Its performance is further evaluated through user trials using the ring-in-loop setup. The user trials demonstrate benefits of the 3DOF workspace of the device along with its teleoperation control. RMF-3 offers an improved workspace and reachability within the laryngeal region. Surgeons, in their preliminary evaluation of the device, appreciated the ability to articulate the tip, along with rotation, for hard-to-reach parts of the surgical site. RMF-3 offers an ergonomic robotic teleoperation control interface which overcomes hand tremors and extreme wrist excursion which leads to surgeon pain and discomfort.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleDesign and Modeling of a Three-Degree-of-Freedom Articulating Robotic Microsurgical Forceps for Trans-Oral Laser Microsurgery
dc.typeJournal Paper
dc.journal.volume13
dc.journal.issue2
dc.journal.titleJournal of Medical Devices
dc.identifier.doi10.1115/1.4043017
dc.journal.fristpage21006
dc.journal.lastpage021006-9
dc.treeJournal of Medical Devices:;2019:;volume( 013 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record