    Wind Effects on a Tall Building with Square Cross-Section and Mid-Side Base Columns: Database-Assisted Design Approach

    Thumbnail
    View/Open
    %28ASCE%29ST.1943-541X.0002328.pdf (1.165Mb)
    Date
    2019
    Author
    Sejun Park;Dat Duthinh;Emil Simiu;DongHun Yeo
    Metadata
    Show full item record
    Abstract
    This paper illustrates the application of the database-assisted design (DAD) method to the wind design of high-rise buildings. The paper uses publicly available wind tunnel data and DAD procedures to compare responses to (1) corner winds and (2) face winds of a high-rise building of square cross-section supported by a central core column and four mid-side legs. The responses being considered consist of overturning moments, and of demand-to-capacity indexes (DCIs) of selected members, including multistory chevron braces. The analysis accounts for structural dynamics and second-order load-deformation effects. The results show that corner winds are less demanding than face winds, both globally (overturning moments) and locally (DCIs). The along-wind and across-wind overturning moments in the corner wind case are about 20% and 50% lower, respectively, than their counterparts in the face-wind case. The peak axial forces in the legs (peak refers to absolute value) and the peak DCIs in the mid-side mast columns (continuation of the legs) induced by corner winds are lower by 20%–30% than their counterparts due to face winds. The investigation confirms that the building code of the City of New York in effect in the early 1970s can be interpreted as meaning that the design for wind of structures with a square shape in plan may be performed by assuming the wind loads to act normal to a face of the building. The building analyzed in this paper is similar to the Citicorp Building (completed in 1977, later renamed Citigroup Center, now called 601 Lexington) and the results of the analyses presented herein suggest that a re-examination of the history of the Citicorp Building design and retrofit may be warranted.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4257235
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV