Show simple item record

dc.contributor.authorKeller, Stefan
dc.contributor.authorÖzel, Tansu
dc.contributor.authorScherzer, Anne-Christine
dc.contributor.authorGerteisen, Dietmar
dc.contributor.authorGroos, Ulf
dc.contributor.authorHebling, Christopher
dc.contributor.authorManoli, Yiannos
dc.date.accessioned2019-02-28T11:13:59Z
dc.date.available2019-02-28T11:13:59Z
dc.date.copyright2/6/2018 12:00:00 AM
dc.date.issued2018
dc.identifier.issn2381-6872
dc.identifier.otherjeecs_015_02_021002.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4254109
dc.description.abstractElectrochemical impedance spectroscopy is used during operation of different polymer electrolyte membrane fuel cell (PEMFC) stack assemblies at various conditions with special interest given to the characteristic time constant τlow-f derived from the low-frequency arc of the spectra which is typically in the range of approximately 15–0.5 Hz. This was done by fitting an equivalent electrical circuit (EEC) consisting of one resistor and two RC-elements to the data. Parameter variation performed on a 90-cell stack assembly suggests that conditions leading to different air flow velocities in the flow channels affect τlow-f while other parameters like humidity influence the impedance spectrum, but not τlow-f. Comparison of the stoichiometry variation between short stack and locally resolved single cell shows similar results with the stack's time constant matching that of the cell's segments which are located off-center toward the outlet. However, a nonlinear dependency between gas flow velocity and τlow-f especially at low stoichiometric values is obvious. Results from stoichiometry variations at different pressure levels suggest that this could be attributed to the different steady-state oxygen partial pressures during the experiments. Comparison of the stoichiometry variation between different stack platforms result in similar dependencies of τlow-f on air flow rate with respect to a reference oxygen partial pressure regardless of size, flow field, geometry, or cell count of the stack. The time constant caused by oxygen diffusion through the gas diffusion layer (GDL), τGDL, was approximated and compared to τlow-f. While it was found that τlow-f ≫ τGDL at low stoichiometric values, τlow-f decreases toward τGDL at very high gas flow rates, suggesting that τGDL offsets τlow-f and becomes dominating if no oxygen concentration variation along the flow channel was present.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleCharacteristic Time Constants Derived From the Low-Frequency Arc of Impedance Spectra of Fuel Cell Stacks
dc.typeJournal Paper
dc.journal.volume15
dc.journal.issue2
dc.journal.titleJournal of Electrochemical Energy Conversion and Storage
dc.identifier.doi10.1115/1.4038632
dc.journal.fristpage21002
dc.journal.lastpage021002-10
dc.treeJournal of Electrochemical Energy Conversion and Storage:;2018:;volume( 015 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record