• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Vibration and Acoustics
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Vibration and Acoustics
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Optimum Tuning of Passive Tuned Mass Dampers for the Mitigation of Pulse-Like Responses

    Thumbnail
    View/Open
    vib_140_06_061014.pdf (4.084Mb)
    Date
    2018
    Author
    Salvi, Jonathan
    Rizzi, Egidio
    Rustighi, Emiliano
    Ferguson, Neil S.
    Metadata
    Show full item record
    Abstract
    Tuned mass dampers (TMDs) are typically introduced and calibrated as natural passive control devices for the vibration mitigation of the steady-state response of primary structures subjected to persistent excitations. Otherwise, this work investigates the optimum tuning of TMDs toward minimizing the transient structural response. Specifically, a single-degree-of-freedom (SDOF) system is considered as a primary structure, with added TMD, subjected to pulse-like excitations. First, the system is analytically analyzed, within the time domain, for unit impulse base displacement, through Laplace transform. Then, the tuning process is numerically explored by an optimization procedure focused on an average response index, to extract the optimum condition toward best TMD calibration. The efficiency of the proposed control device is then assessed and demonstrated through further post-tuning numerical tests, by considering as dynamic loadings: first, a time unit impulse base displacement, coherent with the source description above; second, different pulse-like excitations, to detect the effectiveness of the so-conceived TMD for generic ideal shock actions; third, a set of nonstationary earthquake excitations, to enquire the achievable level of seismic isolation. It is shown that this leads to a consistent passive TMD in such a transient excitation context, apt to mitigate the average response. Additionally, the present tuning forms a necessary optimum background for a possible upgrade to a hybrid TMD, with the potential addition of an active controller to the so-optimized TMD, to achieve even further control performance, once turned on, specifically for abating the peak response, too.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4253477
    Collections
    • Journal of Vibration and Acoustics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV