• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Solar Energy Engineering
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Solar Energy Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Numerical Investigation of Thermal Separators Within the Evacuated Tubes of a Water-in-Glass Solar Water Heater

    Thumbnail
    View/Open
    sol_140_06_061014.pdf (2.502Mb)
    Date
    2018
    Author
    Soopee, Asif
    Khoodaruth, Abdel Anwar Hossen
    Murdan, Anshu Prakash
    Oree, Vishwamitra
    Metadata
    Show full item record
    Abstract
    The effects of thermal separators within the evacuated tubes of a water-in-glass solar water heater (SWH) were numerically investigated using the commercial computational fluid dynamics (CFD) software ANSYS fluent. To validate the three-dimensional (3D) model, an experiment was performed for the passive operation of the SWH for a fortnight period, of which 3 h of recorded data was selected. The Boussinesq's approximation was employed, and the respective solar irradiance and ambient temperature profiles were incorporated. A maximum deviation of only 2.06% was observed between the experimental and numerical results. The model was then adapted for the case where thermal separators are inserted within the evacuated tubes of the SWH and both cases were run for two tilt angles, 10 deg and 40 deg. The temperature and velocity profiles within the evacuated tubes were analyzed alongside the temperature contours, thermal stratification, and overall thermal efficiency of the SWH. At a 40 deg tilt, without thermal separators, the flow streams within the evacuated tubes are restrained, and a chaotic thermal behavior was observed, thereby restricting thermal distribution to the water stored in the SWH tank. A lower tilt angle (10 deg) provided a more desirable thermal distribution. With thermal separators, however, the tilt angle preference was reversed. A faster and more uniform thermal distribution was achieved within the water tank, with a sizeable reduction in the thermal stratification at a 40 deg tilt. The overall thermal efficiency of the SWH was improved by 4.11% and 4.14% for tilt angles of 10 deg and 40 deg, respectively.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4252947
    Collections
    • Journal of Solar Energy Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV