Show simple item record

dc.contributor.authorMahdavi, H. R.
dc.contributor.authorRahimi, G. H.
dc.contributor.authorFarrokhabadi, A.
dc.date.accessioned2019-02-28T11:06:52Z
dc.date.available2019-02-28T11:06:52Z
dc.date.copyright11/30/2017 12:00:00 AM
dc.date.issued2018
dc.identifier.issn0094-9930
dc.identifier.otherpvt_140_01_014501.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4252825
dc.description.abstractIn this paper, the ultimate hoop strength of an industrial (±55 deg)9 filament-wound glass-reinforced epoxy (GRE) pipe as a short-term test is determined according to the ASTM D-1599 standard by performing the internal hydrostatic pressure test. After the test, the failure surface of the pipe is photographed by a high magnification camera, and in addition, the explanations are presented about the type of failure. The main purpose of this study is to compare the results obtained for the ultimate hoop strength and failure mechanisms of the pipe by using the internal hydrostatic pressure test with that by the split disk test method according to the ASTM D-2290 standard in the previous work.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleFailure Analysis of Glass-Reinforced Epoxy Pipes Under Internal Hydrostatic Pressure: A Comparison With the Split Disk Test Method
dc.typeJournal Paper
dc.journal.volume140
dc.journal.issue1
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.4038484
dc.journal.fristpage14501
dc.journal.lastpage014501-4
dc.treeJournal of Pressure Vessel Technology:;2018:;volume( 140 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record