Show simple item record

dc.contributor.authorSelcan Turker, N.
dc.contributor.authorYekta Özer, A.
dc.contributor.authorKutlu, Burak
dc.contributor.authorNohutcu, Rahime
dc.contributor.authorColak, Seyda
dc.contributor.authorEkizoglu, Melike
dc.contributor.authorÖzalp, Meral
dc.date.accessioned2019-02-28T11:04:57Z
dc.date.available2019-02-28T11:04:57Z
dc.date.copyright4/5/2018 12:00:00 AM
dc.date.issued2018
dc.identifier.issn1932-6181
dc.identifier.othermed_012_02_021005.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4252479
dc.description.abstractThis presents the influence of gamma irradiation on Pharmacopeia specifications, mechanical and flow parameters of polypropylene (PP) syringes. There has been significant progress in the terminal sterilization of single-use, disposable medical devices with gamma radiation sterilization due to the growing awareness of toxic residues during the ethylene oxide (EtO) sterilization. PP is a widely used polymer for the production of syringes because of its excellent mechanical and thermal properties and has expanded continuously over the last decade. Although 25 kGy was generally recommended for the gamma radiation sterilization of medical products, this radiation dose is high enough to produce substantial damage. Electron spin resonance (ESR) characteristics of irradiated syringes were also studied at normal (25 °C, 60% relative humidity) and accelerated (40 °C, 75% relative humidity) stability test conditions. It was found that the chemical and radiolytic changes and sterility assurance levels (SAL) after gamma radiation sterilization were different in PP syringes. It was shown that for two commercial syringes, E1 and E3, a SAL of 10−4 could be attained with only 10 kGy, with there being less detrimental radiation effects on E1. The differences in the radiosensitivity of the propylene syringes could be due to the different formulations and manufacturing processes. The results indicated that a commercial syringe, identified as E1 could be safely sterilized with gamma irradiation as the radicals decay over a period of days under normal conditions and quenched much faster under stability conditions. Furthermore, ESR technique could be used successfully in monitoring the radiosterilization of this material. Additionally, the confirmation and validation of the SAL doses which are below 25 kGy, will decrease the time and cost of the sterilization with less damaging effects of ionizing irradiation.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleThe Effect of Different Sterilization Methods on Polypropylene Syringes
dc.typeJournal Paper
dc.journal.volume12
dc.journal.issue2
dc.journal.titleJournal of Medical Devices
dc.identifier.doi10.1115/1.4039434
dc.journal.fristpage21005
dc.journal.lastpage021005-11
dc.treeJournal of Medical Devices:;2018:;volume( 012 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record