Show simple item record

dc.contributor.authorDutra, Brian
dc.contributor.authorCarmen Mora, Maria
dc.contributor.authorGerhardson, Tyler I.
dc.contributor.authorSporbert, Brianna
dc.contributor.authorDufresne, Alexandre
dc.contributor.authorBittner, Katharine R.
dc.contributor.authorLovewell, Carolanne
dc.contributor.authorRust, Michael J.
dc.contributor.authorTirabassi, Michael V.
dc.contributor.authorMasi, Louis
dc.contributor.authorLipkens, Bart
dc.contributor.authorKennedy, Daniel R.
dc.date.accessioned2019-02-28T11:04:46Z
dc.date.available2019-02-28T11:04:46Z
dc.date.copyright1/19/2018 12:00:00 AM
dc.date.issued2018
dc.identifier.issn1932-6181
dc.identifier.othermed_012_01_011008.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4252444
dc.description.abstractRetransfusion of a patient's own shed blood during cardiac surgery is attractive since it reduces the need for allogeneic transfusion, minimizes cost, and decreases transfusion related morbidity. Evidence suggests that lipid micro-emboli associated with the retransfusion of the shed blood are the predominant causes of the neurocognitive disorders. We have developed a novel acoustophoretic filtration system that can remove lipids from blood at clinically relevant flow rates. Unlike other acoustophoretic separation systems, this ultrasound technology works at the macroscale, and is therefore able to process larger flow rates than typical micro-electromechanical system (MEMS) scale acoustophoretic separation devices. In this work, we have first demonstrated the systematic design of the acoustic device and its optimization, followed by examining the feasibility of the device to filter lipids from the system. Then, we demonstrate the effects of the acoustic waves on the shed blood; examining hemolysis using both haptoglobin formation and lactate dehydrogenase release, as well as the potential of platelet aggregation or inflammatory cascade activation. Finally, in a porcine surgical model, we determined the potential viability of acoustic trapping as a blood filtration technology, as the animal responded to redelivered blood by increasing both systemic and mean arterial blood pressure.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleA Novel Macroscale Acoustic Device for Blood Filtration
dc.typeJournal Paper
dc.journal.volume12
dc.journal.issue1
dc.journal.titleJournal of Medical Devices
dc.identifier.doi10.1115/1.4038498
dc.journal.fristpage11008
dc.journal.lastpage011008-7
dc.treeJournal of Medical Devices:;2018:;volume( 012 ):;issue: 001
dc.contenttypeFulltext