• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Heat Transfer
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Heat Transfer
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Influence of Rotating Directions on Hydrothermal Characteristics of a Two-Pass Parallelogram Channel With Detached Transverse Ribs

    Thumbnail
    View/Open
    ht_140_10_102004.pdf (6.676Mb)
    Date
    2018
    Author
    Liou, Tong Miin
    Chang, Shyy Woei
    Huang, Chih Yung
    An Lan, I
    Chan, Shu Po
    Metadata
    Show full item record
    Abstract
    The detailed Nusselt number distributions on leading and trailing endwalls together with the Fanning friction factors of a rotating two-pass parallelogram ribbed channel are simultaneously measured under forward and backward rotations. The tested Reynolds number, rotation number, density ratio, and buoyancy number are respectively in the ranges of 5000 < Re < 15,000, 0 < Ro < 0.3, 0.044<Δρ/ρ < 0.2, and 0 < Bu < 0.142. The area-averaged leading and trailing Nusselt numbers at forward rotations are 0.69–1.77 and 0.85–1.98 relative to the static-channel Nusselt number references, respectively. With backward rotations, the ratios of regionally averaged Nusselt numbers between rotating and static channels for leading and trailing endwalls fall in the respective range to 0.86–2 and 0.91–1.76. At both forward and backward rotations, all the f factors over leading endwall (LE) and trailing endwall (TE) are elevated from the static-channel levels and increased by increasing Ro. Channel averaged f/f0 ratios are respectively raised to 1.21–2.21 and 1.21–2.1 at forward and backward rotations. As the heat transfer enhancements (HTE) attributed to the presence of detached transverse ribs taking precedence of the accompanying f augmentations, all the thermal performance factors are above unity in the range of 1.26–2.94. Relative to the similar rotating two-pass parallelogram channel with attached 90 deg ribs, the detached ribs generate the higher degrees of heat transfer enhancements with the larger extents of f augmentations.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4251779
    Collections
    • Journal of Heat Transfer

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV